Cold-climate myths

Four claims that travel well in the North, set next to the document that answers them.

Last updated: October 17, 2026

“They stop working below freezing.”

Freezing is 0°C. The cold-climate listing test is at −15°C, and it requires the unit to still deliver at least 70 percent of its rated capacity and a COP of at least 1.8. NRCan NRCan’s own guide describes air-source units running well below freezing, with a minimum operating temperature often somewhere between −15°C and −25°C. NRCan guide Below freezing is the normal operating range, not the failure point.

“A cold-climate model carries the house at −40.”

Whitehorse and Yellowknife are both −41°C at the January 2.5% design temperature. NRC tables Yukon’s dual-fuel rule asks for a balance point of −20°C, not −41°C, and it asks for oil, propane, or wood beside the heat pump. Terms The Yellowknife monitoring note says a secondary source was still required in extreme cold. AEA A unit can be excellent and still not be the only heat in the house.

“Yukon banned electric heat pumps.”

The September 3, 2026 terms still pay for heat pumps: dual fuel up to $15,000, Good Energy up to $10,500 on an existing home, and the Affordable Heat Pump Program up to $24,000. What the new program pushes is a non-electric backup on electrically heated houses, because the grid problem is peak demand in a cold snap. All-electric is a different path, with Peak Smart enrollment in the Good Energy rules. It is not a ban.

“The rated tonnage is the tonnage at −30.”

Rated heating capacity is at 8.3°C. Capacity maintenance tells you the fraction still there at −15°C. Nothing on the listing sticker is a measurement at −30°C or −40°C. If the manufacturer does not publish a capacity at that temperature, nobody on a forum knows it either.

Related pages

Sources

Every figure on this page comes from the documents below. If a later official update conflicts, the official update wins.

  1. NRCan heat pump guide

    Balance point, supplementary heat, and operation below freezing as a normal part of the design.

  2. NRCan listing criteria

    Cold-climate units are tested at −15°C, not certified to carry a house at −40°C.

  3. Yukon terms

    −20°C balance point and a required non-electric backup for dual fuel. Good Energy and AHPP still exist for heat pumps.

  4. AEA Yellowknife note

    Secondary heat still required in extreme cold.

  5. NRC climatic tables

    Whitehorse and Yellowknife January 2.5% design temperature −41°C.